EX-FLOW Series |
|
Accuracy (incl. linearity) (based on actual calibration) |
standard: ±1% FS; other on request (for flow > 1000 m3 n/h contact factory) |
Turndown |
1 : 50 (2~100%) |
Repeatability |
< ±0,2% Rd |
Time constant |
5 seconds |
Operating temperature |
EX-FLOW sensor: -10~+70°C; XB-coil: -40~+ 65°C XC-coil: -40~+ 65°C |
Temperature sensitivity |
zero: < ±0,05% FS/°C; span: < ±0,05% Rd/°C |
Leak integrity |
tested < 2 x 10-9 mbar l/s He |
Attitude sensitivity |
max. error at 90° off horizontal 0,2% at 1 bar, typical N2 |
Ingress protection (housing) |
IP65 |
I/O signals via PS/Readout (located in safe area) |
analog: 0~5 Vdc, 0~10 Vdc, 0~20 mA, 4~20 mA; |
I/O signals via PS/Readout (located in safe area) |
digital: RS232, PROFIBUS DP, DeviceNet™, Modbus RTU or ASCII, PROFINET, EtherCAT®, FLOW- BUS |
Material (wetted parts) |
stainless steel 316L or comparable |
Seals |
standard: Viton® options: EPDM, FFKM (Kalrez®), FDA and USP Class VI approved compounds |
어플리케이션 |
• 석유/화학 산업에서 공정가스 측정 및 제어
• 연료 전지 기술
• 가스 분배 시스템
• 수소(H2) 공정
• 내부 회계를 위한 가스 소비량 측정
• 난방 또는 바이오 가스 생산 |
EX-FLOW Series
l IP 65 방진 방수
Mass Flow Meter (MFM) |
Ranges |
Type of process connections |
Series F-110CX |
min.
0,16 ~ 8 mln/min |
Compression type couplings |
Series F-111BX |
min.
0,2 ~ 10 mln/min |
Compression type couplings |
Series F-111AX |
min.
0,1 ~ 5 ln/min |
Compression type couplings |
Series F-112AX |
min.
0,2 ~ 10 ln/min |
Compression type couplings |
Series F-113AX |
min.
2 ~ 100 ln/min |
Compression type couplings |
Series |
min.
0,4 ~ 20 m3n/h |
Compression type couplings |
Series |
min.
0,4 ~ 20 m3n/h |
"wafer
type" for mounting |
Series |
min.
0,4 ~ 20 m3n/h |
flanged
connection |
Mass Flow Meter (MFC) |
Ranges |
Series F-200CX 1) |
min. 0,2
~ 10 mln/min |
Series F-201CX 1) |
min. 0,22
~ 11 mln/min |
Series F-201AX 1) |
min. 0,1
~ 5 ln/min |
Series F-202AX 2) |
min. 0,2
~ 10 ln/min |
Series F-203AX 2) |
min.
2 ~ 100 ln/min |
Series F-206AX/BX 2) |
min.
0,4 ~ 20 m3n/h |
Series
F-230MX/ |
min.
0,2 ~ 10 mln/min |
1) with small type of valve for normal applications 2) with pilot-operated valve for high flow applications 3) with vary-p-valve for high (differential) pressure applications up to 400 bar |