FLUXUS F706

4-Beams for Precision, Reliability and Repeatability

제품사양

Flow channels

4

Quantities

of measurement

Standard Volume Flow (Liquids): In accordance with TP-25, ASTM 1250, DA311

Quantities

of measurement

Further: Volume and mass flow, flow velocity, product/media detection

Medium

Liquid Hydrocarbons and Chemicals

Flow velocity range

0.01m/s … 25 m/s

Measurement accuracy (standard)

±1% of reading, ±0.01 m/s

Measurement accuracy
(field calibrated)

better than ±0.5% of reading, ±0.01 m/s

Repeatability

0.15% of reading, ±0.01 m/s

Media temperature

-40°C … +200°C (-190°C … +600°C with WaveInjector mounting fixture)

Operating temperature of the transmitter

-40°C … +60°C

Pipe diameter range

6mm to 6500mm (independent of pipe wall thickness)

Degree of protection

Transmitter: IP66, Transducers: up to IP68

Available Hazardous Area Classification (optional)

ATEX / IECEx Zone 2; FM Class I, Div. 2

Communication Protocol

HART, Modbus RTU, Modbus TCP, RS485

Inputs

Up to 4 Inputs (temperatue Pt100/Pt1000), current, voltage, binary

Outputs

Up to 4 Outputs: (active/passive) current, voltage, frequency, binary

Advantages

Easy installation without process outages

  • Highly Economical: No heavy equipment necessary for installation, thus being the ideal solution for remote locations, or poorly accessible areas.
  • 100% plant availability: The non-invasive measurement technology does not require any process shut-downs – neither for installation nor for any potential maintenance efforts
  • Extremely low maintenance – virtually zero maintenance due to use of solid couplant pads instead of high maintenance gels
  • Safety: The F706 clamp-on meter does not add any leakage risk. It also does not require any flanges or gaskest.

Laboratory Accuracy under Field Conditions

High accuracy and proven laboratory performance under reference conditions is one task. Accuracy under field conditions is quite another thing:

  • FLEXIM‘s transducers automatically compensate for ambient temperature changes – according to ANSI/ASME MFC-5.1-2011. This ensures no false measurement readings during temperature swings (day / night)
  • FLEXIM‘s transducers are carefully paired according to their individual properties. This process lays the foundation for superior accuracies over a wide temperature and application range. It also ensures a negligible zero offset and facilitates the measurement of very low flow rates. There is no need for zeroing, or programmed “automatic zero” workarounds.
  • FLEXIM‘s transducers are all individually factory calibrated, with storage of the calibration data on a “Sensprom”chip. The calibrated transmitter automatically reads the individual calibration data, avoiding potential errors and making transducer exchanges easy.

For FLEXIM, accuracy is a topic we take seriously. FLEXIM‘s specified installed-accuracy claims can seem conservative but we firmly believe that clients expect us to over-perform rather than disappoint. Ask us, if you want to learn more about the total measurement uncertainty for your specific application.