FLUXUS G608

The portable Flowmeter for Gases in Hazardous Areas

제품사양

Flow channels

2

Operating temperature of the transmitter

-10°C … +60°C

Degree of protection

IP65

Explosion of protection

ATEX / IECEx Zone 2 and FM Class I, Div. 2,

Transducers:

ATEX / IECEx Zone 1 and 2 and FM Class I, Div. 1 /2

Accuracy

±1… 3% of reading ±0.01 m/s depending on the application

±0.5% of reading ±0.01 m/s field calibrated

Battery

Li-Ion, 7.2 V/4.5 Ah, > 14 hours operating time

Weight of Transmitter

1.9kg

outputs

2 x current, 2 x binary

Calculation of the standard volume flow based on AGA-8 / ISO 12213-1

Yes

Media temperature

-40°C … 100°C

Pipe diameter range

6 mm … 2100 mm

Operating pressure range

from atmospheric pressure upwards for plastic pipes from 3 bar upwards for metal pipes, no upper pressure limitation

Flow velocity range

0,01 … 35 m/s (dependent on pipe size)

Additional Notes

The G608 is also able to measure liquids. Please consult the F608 Specifications sheet.

Advantages

Extremely resistant

  • High impact Carbon Fiber housing
  • Rugged transducer design
  • Designed for ATEX, IECEx and FM Zones, IP65
  • Compact and very lightweight

Instantly in Service

  • Direct access to hazardous areas
  • Fast and easy set-up (less than 5 minutes)
  • Automatic transducer recognition
  • Intuitive user guidance

Highly Versatile

  • Unrivaled application range
  • Superior accuracy even with media containing solids
  • Integrated high capacity Li-Ion battery (>14 hrs. of remote measuring)

Accurate and Reliable

  • All transducers are wet calibrated
  • High precision during high and low flow rates
  • No temperature and zero drift